Order by: Relevance
Price: Low to High, High to Low

 
Image of Murrelektronik 86362 Safety transformer 1 x 230 V AC, 400 V AC 1 x 24 V AC 100 VA
 
£ 51.99
More Information

 
Image of Murrelektronik 86368 Control transformer 1 x 230 V AC, 400 V AC 1 x 230 V AC 100 VA
 
£ 51.99
More Information

 
Image of Murrelektronik 9000-41000-0000212 Electrical potential distribution 1 pc(s)
 

Murrelektronik 9000-41000-0000212 Electrical potential distribution 1 pc(s)

AWG max.: 14; Additional technical information: Connection type: Bridge systemMounting type: Snaps onto mounting rail TH35 (EN 60715)OPERATING VOLTAGE 12 V/DC, 24 V/DCBridge concept: Bridge set (max. 40 A)Cross section (Flex): 0.2 mm² - 2.5 mm² (AWG...

£ 57.99
More Information

 
Image of Murrelektronik 9000-41000-0002206 Electrical potential distribution 1 pc(s)
 

Murrelektronik 9000-41000-0002206 Electrical potential distribution 1 pc(s)

AWG max.: 14; Additional technical information: Connection type: Bridge systemMounting type: Snaps onto mounting rail TH35 (EN 60715)OPERATING VOLTAGE 12 V/DC, 24 V/DCBridge concept: Bridge set (max. 40 A)Cross section (Flex): 0.2 mm² - 2.5 mm² (AWG...

£ 55.99
More Information

 
Image of Murrelektronik 9000-41034-0100400 Electronic fuse 4 A No. of outputs: 4 x
 

Murrelektronik 9000-41034-0100400 Electronic fuse 4 A No. of outputs: 4 x

MICO - the intelligent current distribution. Both line circuit breakers and electronic overcurrent protection devices with current limitation in operation promote the risk of fire, since residual currents continue to flow or operating voltages break down....

£ 159.99
More Information

 
Image of Murrelektronik 9000-41034-0100600 Electronic fuse 6 A No. of outputs: 4 x
 

Murrelektronik 9000-41034-0100600 Electronic fuse 6 A No. of outputs: 4 x

MICO 4.6 is a 4-channel electronic auxiliary circuit switch and serves as current monitoring. The operating voltage (+24V DC/at least 10A) is split into 4 current monitored load circuits (channels). When engaging the operating voltage the switched-on...

£ 169.99
More Information

 
Image of Murrelektronik 9000-41034-0401000 Electronic fuse 10 A No. of outputs: 4 x
 

Murrelektronik 9000-41034-0401000 Electronic fuse 10 A No. of outputs: 4 x

Current MonitoringSelect a maximum individual current value for each channel and MICO wil monitor this value. When the value is within the appropriate range the LED will be solid green.Indication When Current Approaching Maximum LoadWhen 90% of the selected...

£ 169.99
More Information

 
Image of Murrelektronik 9000-41042-0100400 Electronic fuse 4 A No. of outputs: 2 x
 

Murrelektronik 9000-41042-0100400 Electronic fuse 4 A No. of outputs: 2 x

Current MonitoringSelect a maximum individual current value for each channel and MICO wil monitor this value. When the value is within the appropriate range the LED will be solid green.Indication When Current Approaching Maximum LoadWhen 90% of the selected...

£ 134.99
More Information

 
Image of Murrelektronik 9000-41042-0100600 Electronic fuse 6 A No. of outputs: 2 x
 

Murrelektronik 9000-41042-0100600 Electronic fuse 6 A No. of outputs: 2 x

Current MonitoringSelect a maximum individual current value for each channel and MICO wil monitor this value. When the value is within the appropriate range the LED will be solid green.Indication When Current Approaching Maximum LoadWhen 90% of the selected...

£ 119.99
More Information

 
Image of Murrelektronik 9000-41042-0401000 Electronic fuse 10 A No. of outputs: 2 x
 

Murrelektronik 9000-41042-0401000 Electronic fuse 10 A No. of outputs: 2 x

MICO - Intelligent current distribution. Both line switches and electronic overcurrent protection devices with current limitation in operation promote the risk of fire, since fault currents continue to flow or operating voltages break down. This means...

£ 149.99
More Information